An Ex d enclosure is designed to contain an explosion and stop any flames, sparks, and hot gases from escaping into the surrounding atmosphere should an internal explosion occur. In addition, an Ex d enclosure protects the fitted equipment against external moisture, dirt, dust, or water. The enclosure may house equipment such as, contactors, relays, power supplies, transformers, radio devices and other electrical equipment with potentially hot surfaces. Sometimes referred to as ‘flameproof’ or “explosion-proof”, an Ex d enclosure includes what is known as a flame path. The flame path design can vary depending on the construction of the Ex d enclosure system. Flame Path Flame paths are gaps within the enclosure that, if an internal explosion occurs, ensure that by the time the flame has reached the end of the flame path it has […]
Extronics’ trusted partner, MMX Communications needed a custom wireless network solution for a major petrochemical company. The client required a secondary communications link to an existing offshore platform. The secondary link would support a sub-sea cable and use microwave Line of Sight equipment. The electrical equipment also needed to be installed and work in an area on the platform that may have an explosive atmosphere present. Customer Requirements MMX Communications client needed to deploy a NEC iPasolink Digital Radio System and two outdoor units for the radios into a Zone 1 hazardous area of the site. The iPasolink hardware is too big for a lot of standard wireless access point systems available; MMX needed to find a manufacturer who could design a custom solution that still met all the required standards for operations in the […]
The standards surrounding the installation of a wireless access point in hazardous areas are often misinterpreted. It is not uncommon to think you can purchase a NEMA 4X or Ex e enclosure and simply install any wireless access point into your hazardous area. This is not true and overlooks a key clause of the standard assigned to deploying electrical equipment in hazardous areas. This article explains key aspects of the standard to consider when deploying wireless devices into hazardous areas. It also addresses why you cannot just use a NEMA 4X or Ex e enclosure to install none certified wireless access points in hazardous areas. Zone 2/Division 2 Hazardous Area Standards for Deploying Wireless Access Points There are many devices on the market, including WiFi Access Points, UHF RFID Readers, LoRa or BLE Gateways and […]
Received signal strength indication (RSSI) location principle uses received signal strength to determine the location of the transmitting device. A wireless device sends a signal out and that signal is received by a gateway or access point. Multiple access points will pick up the signal and from that a received signal strength is determined by each access point. The further away the access point to the transmitting device the weaker the signal. In comparison, the closer the transmitting device is to an access point the stronger the received signal strength. Location is determined by receiving the signal from multiple access points and taking the different measurements to make an approximation of location by trilateration. The approximate location can then be positioned on a map. For example, an asset or a worker wearing a Wi-Fi RTLS […]
John Hartley, CEO of Extronics, talks about the next generation of site wide Real Time Location Systems (RTLS) using hybrid technology for improved worker safety and asset tracking. Why is location tracking important for worker safety? The safety of workers, whilst always important, is moving higher up the list of priorities for investment. Companies operating within the process industries are always looking to ensure their workers are safe whilst making sure they are getting the biggest ROI possible. Back in 2005, when the first intrinsically safe Active RFID Wi-Fi RTLS tags were made, the goal of the oil and gas industry was to use technology to improve worker safety. This is still true today, though adoption has been slow for various reasons, such as the maturity of available technology and concerns over costs and benefits. […]
The main standards for hazardous area equipment globally are ATEX, IECEx and North American NEC 500/505. For ATEX and IECEx, covering most of the world, the IEC 60079 series of standards are typically used for the approval of equipment installed in hazardous areas. Most national or regional domains derive their own standards from the IECEx standards and issue a version, often identical, as their own national or regional standard. The most frequently used electrical equipment protection standards are: 60079-0 General requirements 60079-1 Explosion proof enclosures 60079-7 Increased safety 60079 -11 Intrinsic safety 60079 -15 Non sparking, hermetic sealing and restricted breathing 60079-18 Encapsulation Who Governs the Hazardous Area Standards? In Europe the ATEX directives ensure that every ATEX certificate must be recognised by a notified body. IEC standards are also already fully accepted in national […]