Indicators, Rate Meters, Counters and Clocks
- Intrinsically Safe
- ATEX II 1G EEx ia IIC T5
- Operating Temp. Range -20°C to +60°C
- IP65
- Intrinsically Safe
- ATEX II 1G EEx ia IIC T5
- Operating Temp. Range -20°C to +50°C
- IP65 Front Panel, IP20 Rear
- Intrinsically Safe
- ATEX II 2G EEx ia IIC T4
- Operating Temp. Range 0°C to +50°C
- Intrinsically Safe
- ATEX II 1G EEx ia IIC T4
- Operating Temp. Range -20°C to +60°C
- IP66
- Intrinsically Safe
- ATEX II 1G EEx ia IIC T5
- Operating Temp. Range -20°C to +60°C
- IP65
- Intrinsically Safe
- ATEX II 1G EEx ia IIC T5
- Operating Temp. Range -20°C to +50°C
- IP66
- Intrinsically Safe
- ATEX II 1G EEx ia IIC T5
- Operating Temp. Range -20°C to +60°C
- IP66
- Intrinsically Safe
- ATEX II 1G EEx ia IIC T5
- Operating Temp. Range -20°C to +60°C
- IP65
- Intrinsically Safe
- ATEX II 1G EEx ia IIC T5
- Operating Temp. Range -20°C to +60°C
- IP66
- Intrinsically Safe
- ATEX II 1G EEx ia IIC T5
- Operating Temp. Range -20°C to +60°C
- IP65
- Intrinsically Safe
- ATEX II 1G EEx ia IIC T5
- Operating Temp. Range -20°C to +60°C
- IP66
- Intrinsically Safe
- ATEX II 1G EEx ia IIC T5
- Operating Temp. Range -20°C to +60°C
- IP65
- Intrinsically Safe
- ATEX II 1G EEx ia IIC T5
- Operating Temp. Range -20°C to +60°C
- IP65
- Intrinsically Safe
- ATEX II 1G EEx ia IIC T5
- Operating Temp. Range -20°C to +60°C
- IP66
- Intrinsically Safe
- ATEX II 1G EEx ia IIC T5
- Operating Temp. Range -20°C to +60°C
- IP65
- Intrinsically Safe
- ATEX II 1G EEx ia IIC T5
- Operating Temp. Range -20°C to +60°C
- IP65
- Europe - ATEX II 1G EEx ia IIC T4
- USA - Entity CL I, II, III Div. 1 Gp A, B, C, D, E, F & G
- Canada - Nonincendive CL I, II, III Div. 2 Gp A, B, C, D, E, F & G
- International - IECEx Ex ia IIC T4
- -40 to 70°C
- IP66
- ATEX II 3G EEx nL IIC T4
- -20 to 70°C
- IP66
- Europe - ATEX II 2G EEx ia IIC T4
- USA FM - Entity CL I Div. 1 Gp A, B, C & D
- Canada FM - Nonincendive CL I Div. 2 Gp A, B, C & D
- International - IECEx Ex ia IIC T4
- -40 to 70°C
- IP66
- Europe - ATEX II 2GD Ex d IIC T6
- IP66 NEMA 4X Enclosure
- -20 to +60°C
- Intrinsically Safe
- ATEX II 1G EEx ia IIC T4
- Operating Temp. Range -20°C to +60°C
- IP65
- Intrinsically Safe
- ATEX II 1G EEx ia IIC T5
- Operating Temp. Range -20°C to +60°C
- IP66
- Intrinsically Safe
- ATEX II 1G EEx ia IIc T5
- Operating Temp. Range -20°C to +60°C
- IP65
- ATEX - II 1G Ga Ex ia IIC T5, II (1) G, [Ex ia] IIC (associated apparatus) Ta = -40 to 70°C
- IECEx - Ga Ex ia IIC T5 [Ex iaGa] IIC (associated apparatus) Ta = -40 to 70°C
- Optional Dust Certification
- IP66
-
Electronics -40 to +70°C
Display -20 to +70°C
- ATEX - Transmitter: II 3GD, Ex nA nL [ia] IIC T5 Ex tD [iaD]
A22 IP66 T80°C Ta = -20 to 60°C
Sensor Input: II (1) G [ia] IIC T5 II (1) D [iaD] - IECEx - Transmitter: Ex nA nL [ia] IIC T5 Ex tD [iaD] A22 IP66
T80°C Ta = -20 to 60°C
Sensor Input: [ia] IIC T5 [iaD] - IP66
-
-20 to +60°C
- ATEX - Transmitter: II 3GD, Ex nA nL [ia] IIC T5 Ex tD [iaD]
A22 IP66 T80°C Ta = -20 to 60°C
- ATEX - II 1G Ga Ex ia IIC T5 Ta = -40 to 70°C
- IECEx - Ga Ex ia IIC T5 Ta = -40 to 70°C
- Front IP66
Rear IP20 - Electronics -40 to +70°C
Display -20 to +70°C