Alarm Annunciators, Sounders and Beacons

BA386

Intrinsically Safe LED Beacon

BA386
  • Intrinsically Safe
  • ATEX II 1G EEx ia IIC T4
  • Operating Temp. Range -20°C to + 60°C
  • IP56

BExA110

Flameproof Voice Sounder

BExA110
  • Flameproof
  • ATEX II 2GD EEx d IIC T4 T100°C
  • Operating Temp. Range -50°C to 55°C
  • IP67

BExBG

Flameproof Xenon Warning Beacons

BExBG
  • Flameproof
  • ATEX II 2GD EEx d IIC T5 T100°C
  • Operating Temp.-50°C to 55°C
  • IP67

BExBGL1D

EEx LED Hazardous Area Beacon/ Status Light

BExBGL1D
  • Flameproof
  • II 2G/D EEx d IIC T4 T105°C/T5 T95°C
  • Operating Temp: -50 to +55°C (EExd IIC T4)/-50 to +40°C (EExd IIC T5)
  • IP67

BExCA110-05D

Flameproof EEx Combined Voice Sounder & Beacon

BExCA110-05D
  • Flameproof
  • ATEX II 2GD EEx d IIB T4 T100°C
  • Operating Temp. Range -50°C to 55°C
  • IP67

BExCBG05-05D

Flameproof Dual Xenon Beacon

BExCBG05-05D
  • Flameproof
  • ATEX II2GD EEx d IIC T5 T100°C
  • Operating Temp. Range -55°C to +55°C
  • IP67

BExCL15-05D

FlameProof EEx Combined Loudspeaker & Beacon

BExCL15-05D
  • Flameproof Dust Ignition Proof
  • ATEX II 2GD EExd IIB T4 T100°C
  • Operating Temp. Range -50°C to 55°C
  • IP67

BExCS110-05D

FlameProof EEx Combined Alarm/Sounder & Beacon

BExCS110-05D
  • Flameproof & Dust Ignition Proof
  • ATEX II 2GD EExd IIB T4 T100°C
  • Operating Temp. Range -50 to +55°C
  • IP67

BExS110

Flameproof Hazardous Area Alarm Sounders

BExS110
  • Flameproof
  • ATEX II 2GD EEx d IIC T4 T100°C
  • Operating Temp.Range -50°C to +55°C
  • IP66&67

BExTBG05D

Flameproof Telephone Initiated Xenon Warning Beacon

BExTBG05D
  • Flameproof & Dust ignition proof
  • ATEX II 2GD EEx d T5 T100°C
  • Operating Temp. Range -50 to +55°C
  • IP67

BExTS110

Flameproof Telephone Initiated Alarm Sounder

BExTS110
  • Flameproof
  • ATEX II 2GD EEx d IIC T4
  • Operating Temp Range -50 to +55°C
  • IP67

BR385

Intrinsically Safe Audible Sounder

BR385
  • Intrinsically Safe
  • ATEX II 1G EEx ia IIC T4
  • Operating Temp. Range -40 to +60C
  • IP66

BR385 - BA386

Intrinsially Safe Sounder Beacon Combination

  • Intrinsically Safe
  • ATEX II 1G EEx ia IIC T4
  • Operating Temp. Range -20°C to + 60°C
  • IP56

dSLD 21

Flameproof Rotating Beacon

dSLD 21
  • Flameproof
  • ATEX II 2G EEx de IIC T6
  • Operating Temp. Range -20°C to +40°C
  • IP66

E2xB05 & E2xB10

5 & 10 Joule Xenon Strobe Beacons

E2xB05 & E2xB10
  • Flameproof
  • II 3G EEx nA nL IIC T2/T3
  • ATEX: IP66 & IP67
  • UL: Type 4, 4X & 13

E2xCS112-05

Combined Alarm Horn Sounder & Xenon Beacon

  • II 3G EEx nA nL IIC T2 (Tamb -20°C to +55°C/T3 (Tamb -20°C to +40°C)
  • ATEX: IP66 & IP67. UL: Type 4, 4X & 13

IS-mA1

IS-minialarm: Alarm Sounder

IS-mA1
  • Atex II 1G EEx ia IIC T4 (-40°C<=Ta<=+60°C)
  • Sealed to IP65
  • Operating temperature: -40 to +60°C

IS-mB1

IS-minialite: L.E.D Beacon

IS-mB1
  • Atex II 1G EEx ia IIC T4 (-40°C<=Ta<=+60°C)
  • Sealed to IP65
  • Operating temperature: -40 to +60°C

IS-mC1

IS-minialert: Alarm Sounder & Beacon

IS-mC1
  • Atex II 1G EEx ia IIC T4 (-40°C<=Ta<=+60°C)
  • Sealed to IP65
  • Operating temperature: -40 to +60°C

LN1000

Intrinsically Safe Alarm Annunciator

LN1000
  • Intrinsically Safe
  • ATEX II 1G EEx ia IIC T4
  • Operating Temp. Range -20°C to +60°C
  • IP65 Front; IP20 Rear.

LN870

Intrinsically Safe Light Tower

LN870
  • Intrinsically Safe
  • ATEX II 2G EEx ia IIC T4
  • Operating Temp. Range -20°C to +60°C
  • IP40

TWIN

Intrinsically Safe Combined Beacon/Sounder for Telephones

TWIN
  • Encapsulated, Increased Safety & Intrinsically Safe
  • ATEX II 2G EEx [ib] em IIC T6
  • Operating Temp. Range -20°C to +40°C
  • IP66